Operating The System
1.1 Introduction
The Moose ZX400/ZX410 Security System incorporates the most desired operational features available today. The ZX400/
ZX410 features ease of installation and programming with an easy-to-operate keypad. Features such as cross-zoning, delay
before dialing, and an audibles “mute” function on the keypad help reduce false alarms. The ZX400/ZX410 also provides
two truly independent partitions which allow the system to be divided into two distinct fully functional areas.
The ZX400/ZX410 is pre-programmed at the factory with one 2-wire smoke detector zone and twelve burglar zones (one
delay, two interior, and nine instant) through Moose’s unique “2 in 1” Zoning™. A Zone Expander Module (ZXEXP) may
be added to provide an additional 2-wire smoke detector zone and up to 16 additional zones.
The ZX400/ZX410 Security Control is easily programmed with any one of four ZX400/ZX410 Controls Stations (LCD,
LED, SSD, or VFD). The Control’s on-board RAM maintains its data even with the power disconnected. The Control may
also be programmed remotely with the aid of a personal computer (PC) and a modem using Moose’s remote programming
software (RPM2PRO) and a panel support module (PRO400).
The ZX400/ZX410 Security Control allows the division of a single system into two distinct areas. To the customer, each
area appears to be a fully functional system. Each zone and Control Station must be assigned to one of the two areas. The
Control Stations may also be extended to operate in the other area as a secondary area. A user passcode may be assigned to
access and control one or both of the areas. The Control may have up to 50 user codes programmed with 15 different levels
of authority.
1.2 Powering Up With The Control Station
The control comes from the manufacturer with a factory set (default) program. The factory default code for user passcode
No. 1 is “1234”. This passcode is authorized to perform all user level functions. The default setting for the installer
passcode is “9632”. The installer passcode can perform the installer level functions. (See section 3.2.4 for the listed
functions.) All zones and Control Stations are assigned to Area 1 at default. The default setting for user passcode No. 50 is
“1245” and it is authorized to perform all user level functions. It is assigned to both Area 1 and 2.
When a Control Station is powered-up, it briefly displays a test pattern followed by its data bus address. The Control
Station will then begin displaying information from the control panel. During the first fifteen seconds after power-up, the
control panel will instruct the Control Station to display the panel’s software revision and flash the AWAY, STAY, NIGHT,
READY, and TROUBLE LEDs.
(NOTE: Rev number may change as software is upgraded)
Once the zones are in a secure state, the Control Station displays:
Nearly every option on the control requires the use of a valid user passcode. The user passcode may be used for functions
in a specific area or system-wide. Most of the options may be performed at any time, even while the control is fully or
partially armed. To perform a function, a user must press the key corresponding to that function and then enter a passcode
with the appropriate authority level. For purposes of discussion, the installer and the end user are both considered system
users, but have different levels of authorization.
PANEL REV 1.04
A1 READY TO ARM
JAN 21 05:27:52
READY
TROUBLE
READY
TROUBLE
WWW.DIYALARMFORUM.COM